Regulatory Submission

How do TEMPO measurements fit in?

This page outlines the measurements that TEMPO provides and the additional tests that you will need for regulatory submission.

 

ENERGY STAR Luminaires 1.1
TEMPO 24 reports provide:
  • IES LM-79-08 photometric report with integrated-sphere and goniophotometric data (including color angular uniformity)
  • In-situ test data
What you will need additionally:
  • Electrical-performance data
    • Start-up time, run-up time, dimming, power factor, off-state power consumption, UUT operating frequency
  • Noise-test data
  • Transient-protection (ring wave) test data
  • EMI / RFI test data
  • Safety report
  • Color / lumen maintenance
    • Option 1: LM-80 data, in-situ test data and TM-21 report
    • Option 2: Run the actual luminaires through lifetime testing
 
ENERGY STAR Integral LED Lamps 1.4 *
* Requirements may change with new draft
TEMPO 24 reports provide:
  • IES LM-79-08 photometric report with integrated sphere and goniophotometer data (including color angular uniformity)
  • In-situ test data
What you will need additionally:
  • Electrical-performance data
    • Dimming, power factor, UUT operating frequency
  • Noise-test data
  • Transient-protection (ring wave) test data
  • EMI / RFI test data
  • Safety report
  • Minimum-operating-temperature validation (outdoor only -20C)
  • Rapid-cycle stress testing
  • Color / lumen maintenance
    • Option 1: LM-80 data, in-situ test data and TM-21 report
    • Option 2: Run the actual luminaires through lifetime testing 
 
DesignLights Consortium
TEMPO 24 reports provide:
  • IES LM-79-08 photometric report with sphere and gonio data
  • In-situ-temperature-measurements-test (ISTMT) report
What you will need additionally:
  • Electrical-performance data
    • Power factor, THD-A / THD-V
  • Noise-test data
  • Color / lumen maintenance
    • Option 1: LM-80 data, in-situ test data and TM-21 report
    • Option 2: Run the actual luminaires through lifetime testing 
 
U.S. DOE Lighting Facts
Federal Trade Commision label
TEMPO 24 reports provide everything:
  • IES LM-79-08 for total flux and color (required label metrics; LM-79 sections 9 and 12)
  • IES LM-7-08 for intensity distribution (optional metrics; LM-79 section 10)
  • In-situ temperature-measurement test (ISTMT)
  • IES LM-80-08